HOMA-IR Calculator

Calculate HOMA-IR, the homeostasis model assessment of insulin resistance, from a fasting glucose and a fasting insulin taken at the same time. This HOMA-IR calculator accepts glucose in mg/dL or mmol/L and insulin in µIU/mL or pmol/L, uses the original formula of 1985[1] and shows how your score compares with published reference values.

By the Gloire team · Formula: Matthews et al., 1985 · Updated November 17, 2026 · How we build and test calculators

For information only — not medical advice.

How to use

  1. Enter your fasting glucose from the lab report and pick its unit.
  2. Enter your fasting insulin from the same blood sample and pick its unit: µIU/mL (also written mU/L or mIU/L) or pmol/L.
  3. Read your HOMA-IR under the form.

Example: a fasting glucose of 90 mg/dL with a fasting insulin of 10 µIU/mL gives a HOMA-IR of 2.22[1]. That is below the cut-off for insulin resistance used in the Bruneck Study[2].

How it is calculated

HOMA is a model of how fasting glucose and fasting insulin hold each other in balance: the pancreas releases insulin, and insulin keeps glucose from rising[1]. Its authors also gave a simple approximation, which most studies use instead of the full computer model, and the calculator uses it too[3]:

HOMA-IR (homeostasis model assessment of insulin resistance)
HOMA-IR = fasting glucose (mmol/L) × fasting insulin (µIU/mL) ÷ 22.5
= fasting glucose (mg/dL) × fasting insulin (µIU/mL) ÷ 405
Insulin and glucose units
Insulin: 1 µIU/mL = 6.00 pmol/L
Glucose: 1 mmol/L = 18 mg/dL

The score is scaled so that 1.0 is the model's reference for healthy, normal-weight adults under 35[3]. In the original study, HOMA-IR agreed well with the glucose clamp, the reference method for insulin resistance (rank correlation 0.88), but single estimates were imprecise, with a coefficient of variation of 31 percent[1].

What the result means

A higher HOMA-IR means that more insulin is needed to hold fasting glucose at its level — that is, more insulin resistance. There is no single normal range.

In the Bruneck Study, a random sample of 888 people aged 40 to 79, the cut-off for insulin resistance was 2.77: the lower edge of the top fifth of HOMA-IR among people who were not obese and had no metabolic disorders[2]. Other studies and laboratories use other cut-offs, because insulin tests and populations differ.

Limits

Frequently asked questions

What is a normal HOMA-IR?

There is no single normal value. The model's reference is 1.0 for healthy, normal-weight adults under 35[3], and the Bruneck Study used 2.77 as the cut-off for insulin resistance[2]. Other populations and laboratories use other cut-offs.

Can I calculate HOMA-IR from a non-fasting sample?

No. The model describes the fasting state, so glucose and insulin must both come from a fasting sample[3].

Why does my lab report a different HOMA-IR?

Laboratories may round differently or convert insulin from pmol/L with another factor. With 6.945 instead of 6.00, the score comes out about 14 percent lower[4].

Sources

  1. Matthews et al., 1985. Homeostasis model assessment: insulin resistance and beta-cell function from fasting plasma glucose and insulin concentrations in man. Diabetologia. doi:10.1007/bf00280883
  2. Bonora et al., 1998. Prevalence of insulin resistance in metabolic disorders: the Bruneck Study. Diabetes. doi:10.2337/diabetes.47.10.1643
  3. Wallace et al., 2004. Use and Abuse of HOMA Modeling. Diabetes Care. doi:10.2337/diacare.27.6.1487
  4. Knopp et al., 2019. Insulin Units and Conversion Factors: A Story of Truth, Boots, and Faster Half-Truths. J Diabetes Sci Technol. doi:10.1177/1932296818805074