A1c Calculator

Convert an HbA1c result to estimated average glucose (eAG) in mg/dL and mmol/L, or estimate A1c from an average glucose. Enter A1c in percent (the NGSP unit used in the US) or in mmol/mol (the IFCC unit used by many labs elsewhere). The calculator uses the equation from the A1c-Derived Average Glucose (ADAG) study[1] and shows where a lab A1c falls in the American Diabetes Association ranges[2].

By the Gloire team · Formula: Nathan et al., 2008 · Updated November 17, 2026 · How we build and test calculators

For information only — not medical advice.

How to use

  1. Choose the direction: A1c → average glucose or Average glucose → A1c.
  2. Enter your value and pick its unit: percent or mmol/mol for A1c, mg/dL or mmol/L for glucose. If you switch the unit after typing, the number you typed is converted.
  3. Read the result under the form. For a lab A1c, it also shows the ADA range the value falls in.

Example: an A1c of 7% corresponds to an estimated average glucose of 154 mg/dL, or 8.6 mmol/L[1]. The same A1c is 53 mmol/mol in IFCC units[3]. In the other direction, an average glucose of 154 mg/dL gives an estimated A1c of 7.0%.

A1c to average glucose chart

The table converts common A1c values with the same equations the calculator uses. Glucose is rounded to whole mg/dL and to one decimal place in mmol/L.

A1c and estimated average glucose (eAG)
A1c, %A1c, mmol/moleAG, mg/dLeAG, mmol/L
5.031975.4
5.5371116.2
6.0421267.0
6.5481407.8
7.0531548.6
7.5581699.4
8.06418310.2
8.56919711.0
9.07521211.8
9.58022612.6
10.08624013.4
10.59125514.1
11.09726914.9
11.510228315.7
12.010829816.5

Average glucose from the ADAG equation[1]; mmol/mol from the IFCC–NGSP master equation[3].

How it is calculated

A1c shows what share of your hemoglobin carries glucose, so it reflects your blood sugar over the past few months. The ADAG study compared A1c with average glucose measured by continuous glucose monitors and fingerstick tests in 507 adults with and without diabetes, and found a straight-line relationship between the two[1]. The calculator uses that line in both directions, and the standard equation that links the two A1c units[3][4]:

Estimated average glucose (eAG) from A1c
eAG (mg/dL) = 28.7 × A1c (%) − 46.7
eAG (mmol/L) = eAG (mg/dL) ÷ 18
A1c from average glucose (the same equation solved for A1c)
A1c (%) = (eAG (mg/dL) + 46.7) ÷ 28.7
A1c units: % (NGSP) and mmol/mol (IFCC)
A1c (%) = 0.09148 × A1c (mmol/mol) + 2.152

What the result means

For a lab A1c test, the American Diabetes Association uses these ranges:

The calculator reads the range in the unit you entered. When you convert average glucose to A1c, the result is an estimate, not a lab test, so no ADA range is shown for it.

eAG is the average glucose that people with a given A1c had in the ADAG study. Your own average can be higher or lower than the eAG for your A1c[1].

Limits

Frequently asked questions

Is eAG the same as the average on my glucose meter?

Not exactly. eAG is the average glucose that people with your A1c had in the ADAG study[1]. The average on a meter or sensor depends on when and how often you measure, so the two can differ.

Why does my lab report A1c in mmol/mol?

Many labs outside the US report A1c in IFCC units, mmol/mol. The calculator converts between mmol/mol and percent with the master equation published by the National Glycohemoglobin Standardization Program[3].

What A1c is in the prediabetes range?

For a lab A1c test, the ADA prediabetes range is 5.7% to 6.4%, or 39 to 47 mmol/mol[2].

Can this calculator tell me if I have diabetes?

No. It converts numbers and shows the published ranges. A diagnosis needs lab tests and a clinician, and a diabetes-range result is confirmed by a second abnormal test[2].

Sources

  1. Nathan et al., 2008. Translating the A1C Assay Into Estimated Average Glucose Values. Diabetes Care. doi:10.2337/dc08-0545
  2. American Diabetes Association, 2026. 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026. Diabetes Care. doi:10.2337/dc26-s002
  3. NGSP. IFCC Standardization. ngsp.org/ifccngsp.asp
  4. Hoelzel et al., 2004. IFCC Reference System for Measurement of Hemoglobin A1c in Human Blood and the National Standardization Schemes in the United States, Japan, and Sweden: A Method-Comparison Study. Clin Chem. doi:10.1373/clinchem.2003.024802